GENERAL INSTRUCTIONS FOR "EXTRA IRNING"
INSTALLATION:
- Remove shipping cleats located on the bottom of the cabinet.
- Install 4 provided leg levelers to bottom of cabinet and
level cabinet.
- The power is controlled by a switch located on top of the cebinet,
(Upright Model) or on the bottom of the cabinet (Table Kodel).
Plug into A.C. only 115 volts, 60 cycles. In low line areas
(105 volts or less) a boost in the output voltage of the
transformer may be obtained by removing the wire from the
115 volt tap of the transformer and rewiring to the 105 volt position.
VOLTAGE CONTROL POTS:
Located on Power Supply Board (P.C. 0080-00904D) and are preset
at the factory. These pots should not be tampered with unless
the Distributor Service Department is contacted.
MUSIC (Meg) AND AMPLIFIER (50K) ADJUSTMENT POTS:
Located on Game Logic Board. (P.C. A084-90700-A642) the 1 Meg
Music Pot raises or lowers the volume of the background music.
The 50K Amplifier Pot raised or lowers all other sounds (Cheer,
Whistle, Bat Strike). See sketch below for pot locations.
MUSIC =POT-——— a AMPLIFIER POT————}|——+ [| PRC. AO84-90700-A642_|
GAME SELECT SWITCH: (Upright - Table Model)
TABLE
UPRIGHT
OPTION
-GAME SELECT
Located on Game Logic Board. (P.C. A084-90700-A642). The Select
Switch is provided to allow Logic Board flexibility. That is, the
same board may be used by positioning all switches as indicated
on sketch above.
COIN AND INNING OPTION SWITCH:
Located on Game Logic Board (P.C. AQ84-90700-A642) and may be
adjusted as indicated on seperate instructions in back-box area.
Since the jacks on the cables of the Upright and Table Model are
different, be sure to plug jacks as indicated below when servicing. 4 PIN 9 PIN HOME 9 PIN VISITOR CONTROL OPEN SELECT COlMTROL [7 SONTROL VEL T I i ol TT 1 UTERUS ORLA haste