Extra Innings Service Bulletin (Mar 22 1978)
Extra Inning (Midway Manufacturing Company, 1978) · Service Bulletin · 1 pages · original scan
Page 1
SERVICE BULLETIN
GAME: EXTRA INNING
SUBJECT: RAMS, PROMS AND ROMS
The EXTRA INNING game micro-processor system has been programmed to detect a defective Ram, Prom and/or Rom. To utilize the test, proceed as follows:
- Set switch #7 to on position (A084-90700-A642).
- Activate coin door tilt switch.
- The Ram test sequence will scan and vertical lines will appear.
- When all Rams are good, the scan will be continuous.
- When a Ram is defective, dark vertical columns will appear (refer to Figure #1 for method of locating a bad Ram).
- When Ram test is completed and all Rams are good, the T.V. screen will blank out to indicate a bad Prom or Rom by displaying letters locating it.
- When Proms and Roms are good, the Ram scan will be continuous.
- Return switch #7 to off position (A084-90700-A642).
- The Ram scan will stop and game will return to normal when the tilt switch is activated.
NOTE: Rams must be good before Prom and Rom test can be made.
Andy Ducay AD: ih 3/22/78