Sea Wolf Service Bulletin Proms and Roms

Sea Wolf (set 1) (Dave Nutting Associates / Midway, 1976) · Service Bulletin · 1 pages · original scan

Page 1

CABLE — MIDCO TELEX NO. 72-1596

PHONE: AREA CODE 312 451-1360

. CHICAGO PHONE: 992-2250 10750 W. GRAND AVENUE e FRANKLIN PARK, ILL. 601317

SERVICE BULLETIN

GAME: Sea Wolf

SUBJECT: Roms and Proms - Self Testing

The Sea Wolf micro-computer system has been programmed to detect a defective prom. To utilize the test, proceed as follows:

  • Set switches #6, #7, and #8 to the 'Off' position (PC 596-904).
  • Activate coin door tilt switch.
  • Operate coin switch manually.
  • When a prom is defective internally, a letter will appear displayed on the TV screen locating the faulty prom (PC 80-900).
  • When all proms are good, the TV screen will display nothing but the waves.
  • Return switches #6, #7, and #8 to normal positions.
  • Activate tilt switch to return game to normal operation.

The above test will not function when the program test itself is defective or a prom fault is external.