CATHODE RAY TOMES

M-4 General Instructions

M-4 (Midway, 1977) · Document · 2 pages · original scan

Page 1

GENERAL INSTRUCTIONS FOR "M-4"

INSTALLATION:

  • Remove shipping cleats located on the bottom of the cabinet.
  • Install (4) provided leg levelers to bottom of cabinet and level

cabinet.

  • The power is controlled by a switch located on top of the cabinet.

Plug into A. C. only, 115 volts, 60 cycles. ‘In low line areas

(115 volts or less) a boost in the output voltage of the trans-

former may be obtained by removing the wire from the 115 volt

top of the transformer,.and rewiring to the 105 volt position.

VOLTAGE CONTROL POTS:

Located on Power Supply Board ( P. C.0080-00904F) and are preset at

the factory. These pots should not be tampered with unless the factor

‘ Service Department is contacted.

AMPLIFIER VOLUME CONTROL POTS:

Located on Game Logic Board (P. C. A 684-90700-C626) and are marked

Right Ampl. and Left Ampl. The volume of each amplifier may be

varied by rotating pots as desired.

METHOD OF PLAY,TIME TEST AND EXTENDED PLAY ADJUSTMENT SWITCHES:

Located on Game Logic Board (P.C. A084-90700-6626) and may be adjusted

as indicated on separate instruction sheet in back box area.

TO SERVICE CONTROL PANEL SWITCHES:

  • Remove Control Panel Cable Jack from Logic Board.
  • Open front Coin Door and release (2)clamps located on each side

of cabinet wall thru door opening.

  • Remove wire nut between main cable and Control Panel thru front

door opening.

  • Remove Control Panel & Service same. MIDWAY MFG. CO. 10601 W. Belmont. Franklin Park, Illinois 60131
Page 2

eMlzuC LM340-12 @)INACO4

23_+SENSE 22K 20000CN 00009 il h |! aly ot (2) IN4004 ca o a iNavc4 y a ‘ S 1 i HocoMe. a Oo Sov.

POWER SUPPLY PC. 80-904F

> « * 4 LED & LAMP RETURN