GENERAL INSTRUCTIONS FOR "M-4"
INSTALLATION:
- Remove shipping cleats located on the bottom of the cabinet.
- Install (4) provided leg levelers to bottom of cabinet and level
cabinet.
- The power is controlled by a switch located on top of the cabinet.
Plug into A. C. only, 115 volts, 60 cycles. ‘In low line areas
(115 volts or less) a boost in the output voltage of the trans-
former may be obtained by removing the wire from the 115 volt
top of the transformer,.and rewiring to the 105 volt position.
VOLTAGE CONTROL POTS:
Located on Power Supply Board ( P. C.0080-00904F) and are preset at
the factory. These pots should not be tampered with unless the factor
‘ Service Department is contacted.
AMPLIFIER VOLUME CONTROL POTS:
Located on Game Logic Board (P. C. A 684-90700-C626) and are marked
Right Ampl. and Left Ampl. The volume of each amplifier may be
varied by rotating pots as desired.
METHOD OF PLAY,TIME TEST AND EXTENDED PLAY ADJUSTMENT SWITCHES:
Located on Game Logic Board (P.C. A084-90700-6626) and may be adjusted
as indicated on separate instruction sheet in back box area.
TO SERVICE CONTROL PANEL SWITCHES:
- Remove Control Panel Cable Jack from Logic Board.
- Open front Coin Door and release (2)clamps located on each side
of cabinet wall thru door opening.
- Remove wire nut between main cable and Control Panel thru front
door opening.
- Remove Control Panel & Service same. MIDWAY MFG. CO. 10601 W. Belmont. Franklin Park, Illinois 60131
eMlzuC LM340-12 @)INACO4
23_+SENSE 22K 20000CN 00009 il h |! aly ot (2) IN4004 ca o a iNavc4 y a ‘ S 1 i HocoMe. a Oo Sov.
POWER SUPPLY PC. 80-904F
> « * 4 LED & LAMP RETURN